Copyright (c) 2006 - 2011, Intel Corporation. All rights reserved.
Copyright (c) 2015, Hisilicon Limited. All rights reserved.
Copyright (c) 2015, Linaro Limited. All rights reserved.
SPDX-License-Identifier: BSD-2-Clause-Patent
Module Name:
MiscSystemManufacturerFunction.c
Abstract:
This driver parses the mMiscSubclassDataTable structure and reports
any generated data to smbios.
Based on files under Nt32Pkg/MiscSubClassPlatformDxe/
**/
#include "SmbiosMisc.h"
/**
This function makes boot time changes to the contents of the
MiscSystemManufacturer (Type 1).
@param RecordData Pointer to copy of RecordData from the Data Table.
@retval EFI_SUCCESS All parameters were valid.
@retval EFI_UNSUPPORTED Unexpected RecordType value.
@retval EFI_INVALID_PARAMETER Invalid parameter was found.
**/
MISC_SMBIOS_TABLE_FUNCTION(MiscSystemManufacturer)
{
CHAR8 *OptionalStrStart;
UINTN ManuStrLen;
UINTN VerStrLen;
UINTN PdNameStrLen;
UINTN SerialNumStrLen;
UINTN SKUNumStrLen;
UINTN FamilyStrLen;
EFI_STRING Manufacturer;
EFI_STRING ProductName;
EFI_STRING Version;
EFI_STRING SerialNumber;
EFI_STRING SKUNumber;
EFI_STRING Family;
EFI_STRING_ID TokenToGet;
EFI_SMBIOS_HANDLE SmbiosHandle;
SMBIOS_TABLE_TYPE1 *SmbiosRecord;
SMBIOS_TABLE_TYPE1 *InputData;
EFI_STATUS Status;
EFI_STRING_ID TokenToUpdate;
CHAR16 *Product;
CHAR16 *pVersion;
EFI_GUID Uuid;
//
// First check for invalid parameters.
//
if (RecordData == NULL)
{
return EFI_INVALID_PARAMETER;
}
InputData = (SMBIOS_TABLE_TYPE1 *)RecordData;
Product = (CHAR16 *) PcdGetPtr (PcdSystemProductName);
if (StrLen(Product) > 0)
{
TokenToUpdate = STRING_TOKEN (STR_MISC_SYSTEM_PRODUCT_NAME);
HiiSetString (mHiiHandle, TokenToUpdate, Product, NULL);
}
pVersion = (CHAR16 *) PcdGetPtr (PcdSystemVersion);
if (StrLen(pVersion) > 0)
{
TokenToUpdate = STRING_TOKEN (STR_MISC_SYSTEM_VERSION);
HiiSetString (mHiiHandle, TokenToUpdate, pVersion, NULL);
}
UpdateSmbiosInfo(mHiiHandle, STRING_TOKEN (STR_MISC_SYSTEM_SERIAL_NUMBER), SerialNumType01);
UpdateSmbiosInfo(mHiiHandle, STRING_TOKEN (STR_MISC_SYSTEM_MANUFACTURER), SystemManufacturerType01);
TokenToGet = STRING_TOKEN (STR_MISC_SYSTEM_MANUFACTURER);
Manufacturer = HiiGetPackageString(&gEfiCallerIdGuid, TokenToGet, NULL);
ManuStrLen = StrLen(Manufacturer);
TokenToGet = STRING_TOKEN (STR_MISC_SYSTEM_PRODUCT_NAME);
ProductName = HiiGetPackageString(&gEfiCallerIdGuid, TokenToGet, NULL);
PdNameStrLen = StrLen(ProductName);
TokenToGet = STRING_TOKEN (STR_MISC_SYSTEM_VERSION);
Version = HiiGetPackageString(&gEfiCallerIdGuid, TokenToGet, NULL);
VerStrLen = StrLen(Version);
TokenToGet = STRING_TOKEN (STR_MISC_SYSTEM_SERIAL_NUMBER);
SerialNumber = HiiGetPackageString(&gEfiCallerIdGuid, TokenToGet, NULL);
SerialNumStrLen = StrLen(SerialNumber);
TokenToGet = STRING_TOKEN (STR_MISC_SYSTEM_SKU_NUMBER);
SKUNumber = HiiGetPackageString(&gEfiCallerIdGuid, TokenToGet, NULL);
SKUNumStrLen = StrLen(SKUNumber);
TokenToGet = STRING_TOKEN (STR_MISC_SYSTEM_FAMILY);
Family = HiiGetPackageString(&gEfiCallerIdGuid, TokenToGet, NULL);
FamilyStrLen = StrLen(Family);
//
// Two zeros following the last string.
//
SmbiosRecord = AllocateZeroPool(sizeof (SMBIOS_TABLE_TYPE1) + ManuStrLen + 1
+ PdNameStrLen + 1
+ VerStrLen + 1
+ SerialNumStrLen + 1
+ SKUNumStrLen + 1
+ FamilyStrLen + 1 + 1);
if (NULL == SmbiosRecord)
{
Status = EFI_OUT_OF_RESOURCES;
goto Exit;
}
(VOID)CopyMem(SmbiosRecord, InputData, sizeof (SMBIOS_TABLE_TYPE1));
SmbiosRecord->Hdr.Length = sizeof (SMBIOS_TABLE_TYPE1);
SmbiosRecord->Uuid = InputData->Uuid;
Status = GetUuidType1 (&Uuid);
if (!EFI_ERROR (Status))
{
SmbiosRecord->Uuid = Uuid;
}
OptionalStrStart = (CHAR8 *)(SmbiosRecord + 1);
Status = UnicodeStrToAsciiStrS (Manufacturer, OptionalStrStart, ManuStrLen + 1);
ASSERT_EFI_ERROR (Status);
Status = UnicodeStrToAsciiStrS (ProductName, OptionalStrStart + ManuStrLen + 1, PdNameStrLen + 1);
ASSERT_EFI_ERROR (Status);
Status = UnicodeStrToAsciiStrS (Version, OptionalStrStart + ManuStrLen + 1 + PdNameStrLen + 1, VerStrLen + 1);
ASSERT_EFI_ERROR (Status);
Status = UnicodeStrToAsciiStrS (SerialNumber, OptionalStrStart + ManuStrLen + 1 + PdNameStrLen + 1 + VerStrLen + 1, SerialNumStrLen + 1);
ASSERT_EFI_ERROR (Status);
Status = UnicodeStrToAsciiStrS (SKUNumber, OptionalStrStart + ManuStrLen + 1 + PdNameStrLen + 1 + VerStrLen + 1 + SerialNumStrLen + 1, SKUNumStrLen + 1);
ASSERT_EFI_ERROR (Status);
Status = UnicodeStrToAsciiStrS (Family, OptionalStrStart + ManuStrLen + 1 + PdNameStrLen + 1 + VerStrLen + 1 + SerialNumStrLen + 1 + SKUNumStrLen + 1, FamilyStrLen + 1);
ASSERT_EFI_ERROR (Status);
//
// Now we have got the full smbios record, call smbios protocol to add this record.
//
Status = LogSmbiosData( (UINT8*)SmbiosRecord, &SmbiosHandle);
if(EFI_ERROR(Status))
{
DEBUG((EFI_D_ERROR, "[%a]:[%dL] Smbios Type01 Table Log Failed! %r \n", __FUNCTION__, __LINE__, Status));
}
FreePool(SmbiosRecord);
Exit:
if(Manufacturer != NULL)
{
FreePool(Manufacturer);
}
if(ProductName != NULL)
{
FreePool(ProductName);
}
if(Version != NULL)
{
FreePool(Version);
}
if(SerialNumber != NULL)
{
FreePool(SerialNumber);
}
if(SKUNumber != NULL)
{
FreePool(SKUNumber);
}
if(Family != NULL)
{
FreePool(Family);
}
return Status;
}