From 2f7c68cb55ecb7331f2381deb497c27155f32faf Mon Sep 17 00:00:00 2001
From: hc <hc@nodka.com>
Date: Wed, 03 Jan 2024 09:43:39 +0000
Subject: [PATCH] update kernel to 5.10.198

---
 kernel/drivers/hwmon/pmbus/bel-pfe.c |   16 ++++++++--------
 1 files changed, 8 insertions(+), 8 deletions(-)

diff --git a/kernel/drivers/hwmon/pmbus/bel-pfe.c b/kernel/drivers/hwmon/pmbus/bel-pfe.c
index 2c5b853..fc3d9a9 100644
--- a/kernel/drivers/hwmon/pmbus/bel-pfe.c
+++ b/kernel/drivers/hwmon/pmbus/bel-pfe.c
@@ -17,12 +17,13 @@
 enum chips {pfe1100, pfe3000};
 
 /*
- * Disable status check for pfe3000 devices, because some devices report
- * communication error (invalid command) for VOUT_MODE command (0x20)
- * although correct VOUT_MODE (0x16) is returned: it leads to incorrect
- * exponent in linear mode.
+ * Disable status check because some devices report communication error
+ * (invalid command) for VOUT_MODE command (0x20) although the correct
+ * VOUT_MODE (0x16) is returned: it leads to incorrect exponent in linear
+ * mode.
+ * This affects both pfe3000 and pfe1100.
  */
-static struct pmbus_platform_data pfe3000_plat_data = {
+static struct pmbus_platform_data pfe_plat_data = {
 	.flags = PMBUS_SKIP_STATUS_CHECK,
 };
 
@@ -94,16 +95,15 @@
 	int model;
 
 	model = (int)i2c_match_id(pfe_device_id, client)->driver_data;
+	client->dev.platform_data = &pfe_plat_data;
 
 	/*
 	 * PFE3000-12-069RA devices may not stay in page 0 during device
 	 * probe which leads to probe failure (read status word failed).
 	 * So let's set the device to page 0 at the beginning.
 	 */
-	if (model == pfe3000) {
-		client->dev.platform_data = &pfe3000_plat_data;
+	if (model == pfe3000)
 		i2c_smbus_write_byte_data(client, PMBUS_PAGE, 0);
-	}
 
 	return pmbus_do_probe(client, &pfe_driver_info[model]);
 }

--
Gitblit v1.6.2