| 55 | 55 | Flash faults are re-read after strobing the flash. Possible |
|---|
| 56 | 56 | flash faults: |
|---|
| 57 | 57 | |
|---|
| 58 | | - * led-over-voltage - flash controller voltage to the flash LED |
|---|
| 58 | + * led-over-voltage |
|---|
| 59 | + flash controller voltage to the flash LED |
|---|
| 59 | 60 | has exceeded the limit specific to the flash controller |
|---|
| 60 | | - * flash-timeout-exceeded - the flash strobe was still on when |
|---|
| 61 | + * flash-timeout-exceeded |
|---|
| 62 | + the flash strobe was still on when |
|---|
| 61 | 63 | the timeout set by the user has expired; not all flash |
|---|
| 62 | 64 | controllers may set this in all such conditions |
|---|
| 63 | | - * controller-over-temperature - the flash controller has |
|---|
| 65 | + * controller-over-temperature |
|---|
| 66 | + the flash controller has |
|---|
| 64 | 67 | overheated |
|---|
| 65 | | - * controller-short-circuit - the short circuit protection |
|---|
| 68 | + * controller-short-circuit |
|---|
| 69 | + the short circuit protection |
|---|
| 66 | 70 | of the flash controller has been triggered |
|---|
| 67 | | - * led-power-supply-over-current - current in the LED power |
|---|
| 71 | + * led-power-supply-over-current |
|---|
| 72 | + current in the LED power |
|---|
| 68 | 73 | supply has exceeded the limit specific to the flash |
|---|
| 69 | 74 | controller |
|---|
| 70 | | - * indicator-led-fault - the flash controller has detected |
|---|
| 75 | + * indicator-led-fault |
|---|
| 76 | + the flash controller has detected |
|---|
| 71 | 77 | a short or open circuit condition on the indicator LED |
|---|
| 72 | | - * led-under-voltage - flash controller voltage to the flash |
|---|
| 78 | + * led-under-voltage |
|---|
| 79 | + flash controller voltage to the flash |
|---|
| 73 | 80 | LED has been below the minimum limit specific to |
|---|
| 74 | 81 | the flash |
|---|
| 75 | | - * controller-under-voltage - the input voltage of the flash |
|---|
| 82 | + * controller-under-voltage |
|---|
| 83 | + the input voltage of the flash |
|---|
| 76 | 84 | controller is below the limit under which strobing the |
|---|
| 77 | 85 | flash at full current will not be possible; |
|---|
| 78 | 86 | the condition persists until this flag is no longer set |
|---|
| 79 | | - * led-over-temperature - the temperature of the LED has exceeded |
|---|
| 87 | + * led-over-temperature |
|---|
| 88 | + the temperature of the LED has exceeded |
|---|
| 80 | 89 | its allowed upper limit |
|---|