| 8 | 8 | on operating-points-v2, but the driver can also create the "cpufreq-dt" |
|---|
| 9 | 9 | platform_device to compatibility with operating-points. |
|---|
| 10 | 10 | |
|---|
| 11 | | -For more information about the expected DT format [See: ../opp/opp.txt]. |
|---|
| 12 | | - |
|---|
| 13 | | -Optional properties: |
|---|
| 14 | | -In 'operating-points-v2' table: |
|---|
| 15 | | -- rockchip,leakage-voltage-sel: The property is an array of 3-tuples items, and |
|---|
| 16 | | - each item consists of leakage and voltage selector like |
|---|
| 17 | | - <min-leakage max-leakage volt-selector>. |
|---|
| 18 | | - min-leakage: minimum leakage in mA, ranges from 1 to 254. |
|---|
| 19 | | - max-leakage: maximum leakage in mA, ranges from 1 to 254. |
|---|
| 20 | | - voltage-selector: a sequence number which is used to math |
|---|
| 21 | | - opp-microvolt-L<number> roperty in OPP node. |
|---|
| 22 | | - |
|---|
| 23 | | -- rockchip,pvtm-voltage-sel: The property is an array of 3-tuples items, and |
|---|
| 24 | | - each item consists of pvtm and voltage selector like |
|---|
| 25 | | - <min-pvtm max-pvtm volt-selector>. |
|---|
| 26 | | - min-pvtm: minimum frequency count in KHz. |
|---|
| 27 | | - max-pvtm: maximum frequency count in KHz. |
|---|
| 28 | | - voltage-selector: a sequence number which is used to math |
|---|
| 29 | | - opp-microvolt-L<number> roperty in OPP node. |
|---|
| 30 | | -- rockchip,pvtm-freq: Clock frequency in KHz, which is used to set the cpu clock |
|---|
| 31 | | - frequency before get frequency count of pvtm. |
|---|
| 32 | | -- rockchip,pvtm-volt: Voltage in uV, which is used to set the cpu voltage before |
|---|
| 33 | | - get frequency count of pvtm. |
|---|
| 34 | | -- rockchip,pvtm-ch: An array of two integers containing pvtm channel and clock |
|---|
| 35 | | - oscillation ring. |
|---|
| 36 | | -- rockchip,pvtm-sample-time: The number of milliseconds to wait for pvtm to |
|---|
| 37 | | - finish counting. |
|---|
| 38 | | -- rockchip,pvtm-number: An integer indicating the number of sampling points. |
|---|
| 39 | | -- rockchip,pvtm-error: An integer indicating the error between the sample |
|---|
| 40 | | - results. |
|---|
| 41 | | -- rockchip,pvtm-ref-temp: The SoC internal temperature in degree centigrade, the |
|---|
| 42 | | - min-pvtm and max-pvtm in 'leakage-voltage-sel' are |
|---|
| 43 | | - measured at reference temperature. |
|---|
| 44 | | -- rockchip,pvtm-temp-prop: An array of two integers containing proportional |
|---|
| 45 | | - constants which is used to convert the value at current |
|---|
| 46 | | - temperature to reference temperature. The first one is |
|---|
| 47 | | - used when current temperature is below reference |
|---|
| 48 | | - temperature. Conversely, The second one is used when |
|---|
| 49 | | - current temperature is above reference temperature. |
|---|
| 50 | | -- rockchip,pvtm-thermal-zone: A thermal zone node containing thermal sensor, |
|---|
| 51 | | - it's used to get the current temperature. |
|---|
| 52 | | -- rockchip,thermal-zone: A thermal zone node containing thermal sensor, |
|---|
| 53 | | - it's used to get the current temperature. |
|---|
| 54 | | - |
|---|
| 55 | | -- nvmem-cells: A phandle to cpu_leakage data provided by a nvmem device. |
|---|
| 56 | | -- nvmem-cell-names: Should be "cpu_leakage" |
|---|
| 57 | | - |
|---|
| 58 | | -- rockchip,threshold-freq: Clock frequency in KHz, it's used to reduce power |
|---|
| 59 | | - for SoCs with two clusters. |
|---|
| 60 | | -- rockchip,freq-limit: Only one cluster can contain the property, and the |
|---|
| 61 | | - cluster's maximum frequency will be limited to its |
|---|
| 62 | | - threshold frequency, if the other cluster's frequency |
|---|
| 63 | | - is geater than or equal to its threshold frequency. |
|---|
| 64 | | - |
|---|
| 65 | | -Examples: |
|---|
| 66 | | - |
|---|
| 67 | | -cpus { |
|---|
| 68 | | - cpu@0 { |
|---|
| 69 | | - operating-points-v2 = <&cluster0_opp>; |
|---|
| 70 | | - }; |
|---|
| 71 | | -} |
|---|
| 72 | | - |
|---|
| 73 | | -cluster0_opp: opp_table0 { |
|---|
| 74 | | - compatible = "operating-points-v2"; |
|---|
| 75 | | - opp-shared; |
|---|
| 76 | | - rockchip,leakage-voltage-sel = < |
|---|
| 77 | | - 1 24 0 |
|---|
| 78 | | - 25 254 1 |
|---|
| 79 | | - >; |
|---|
| 80 | | - nvmem-cells = <&cpu_leakage>; |
|---|
| 81 | | - nvmem-cell-names = "cpu_leakage"; |
|---|
| 82 | | - |
|---|
| 83 | | - opp@216000000 { |
|---|
| 84 | | - opp-hz = /bits/ 64 <216000000>; |
|---|
| 85 | | - opp-microvolt = <950000 950000 1350000>; |
|---|
| 86 | | - opp-microvolt-L0 = <1050000 1050000 1350000>; |
|---|
| 87 | | - opp-microvolt-L1 = <950000 950000 1350000>; |
|---|
| 88 | | - opp-suspend; |
|---|
| 89 | | - } |
|---|
| 90 | | -}; |
|---|
| 11 | +For more information about the expected DT format [See: ../opp/rockchip-opp.txt]. |
|---|