| 19 | 19 | is separately set for "GND-Open" and "Supply-Open" modes. |
|---|
| 20 | 20 | Channels 0..31 have common low threshold values, but could have different |
|---|
| 21 | 21 | sensing_modes. |
|---|
| 22 | + |
|---|
| 22 | 23 | The low voltage threshold range is between 2..21V. |
|---|
| 23 | 24 | Hysteresis between low and high thresholds can not be lower then 2 and |
|---|
| 24 | 25 | can not be odd. |
|---|
| 26 | + |
|---|
| 25 | 27 | If falling threshold results hysteresis to odd value then rising |
|---|
| 26 | 28 | threshold is automatically subtracted by one. |
|---|
| 27 | 29 | |
|---|
| .. | .. |
|---|
| 34 | 36 | this value then the threshold rising event is pushed. |
|---|
| 35 | 37 | Depending on in_voltageY_sensing_mode the high voltage threshold |
|---|
| 36 | 38 | is separately set for "GND-Open" and "Supply-Open" modes. |
|---|
| 39 | + |
|---|
| 37 | 40 | Channels 0..31 have common high threshold values, but could have different |
|---|
| 38 | 41 | sensing_modes. |
|---|
| 42 | + |
|---|
| 39 | 43 | The high voltage threshold range is between 3..22V. |
|---|
| 40 | 44 | Hysteresis between low and high thresholds can not be lower then 2 and |
|---|
| 41 | 45 | can not be odd. |
|---|
| 46 | + |
|---|
| 42 | 47 | If rising threshold results hysteresis to odd value then falling |
|---|
| 43 | 48 | threshold is automatically appended by one. |
|---|