| 1 | +// SPDX-License-Identifier: GPL-2.0-or-later |
|---|
| 1 | 2 | /* |
|---|
| 2 | 3 | * processor_thermal.c - Passive cooling submodule of the ACPI processor driver |
|---|
| 3 | 4 | * |
|---|
| .. | .. |
|---|
| 6 | 7 | * Copyright (C) 2004 Dominik Brodowski <linux@brodo.de> |
|---|
| 7 | 8 | * Copyright (C) 2004 Anil S Keshavamurthy <anil.s.keshavamurthy@intel.com> |
|---|
| 8 | 9 | * - Added processor hotplug support |
|---|
| 9 | | - * |
|---|
| 10 | | - * ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ |
|---|
| 11 | | - * |
|---|
| 12 | | - * This program is free software; you can redistribute it and/or modify |
|---|
| 13 | | - * it under the terms of the GNU General Public License as published by |
|---|
| 14 | | - * the Free Software Foundation; either version 2 of the License, or (at |
|---|
| 15 | | - * your option) any later version. |
|---|
| 16 | | - * |
|---|
| 17 | | - * This program is distributed in the hope that it will be useful, but |
|---|
| 18 | | - * WITHOUT ANY WARRANTY; without even the implied warranty of |
|---|
| 19 | | - * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU |
|---|
| 20 | | - * General Public License for more details. |
|---|
| 21 | | - * |
|---|
| 22 | | - * ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ |
|---|
| 23 | 10 | */ |
|---|
| 24 | 11 | |
|---|
| 25 | 12 | #include <linux/kernel.h> |
|---|
| .. | .. |
|---|
| 33 | 20 | #define PREFIX "ACPI: " |
|---|
| 34 | 21 | |
|---|
| 35 | 22 | #define ACPI_PROCESSOR_CLASS "processor" |
|---|
| 36 | | -#define _COMPONENT ACPI_PROCESSOR_COMPONENT |
|---|
| 37 | | -ACPI_MODULE_NAME("processor_thermal"); |
|---|
| 38 | 23 | |
|---|
| 39 | 24 | #ifdef CONFIG_CPU_FREQ |
|---|
| 40 | 25 | |
|---|
| .. | .. |
|---|
| 48 | 33 | #define CPUFREQ_THERMAL_MAX_STEP 3 |
|---|
| 49 | 34 | |
|---|
| 50 | 35 | static DEFINE_PER_CPU(unsigned int, cpufreq_thermal_reduction_pctg); |
|---|
| 51 | | -static unsigned int acpi_thermal_cpufreq_is_init = 0; |
|---|
| 52 | 36 | |
|---|
| 53 | 37 | #define reduction_pctg(cpu) \ |
|---|
| 54 | 38 | per_cpu(cpufreq_thermal_reduction_pctg, phys_package_first_cpu(cpu)) |
|---|
| .. | .. |
|---|
| 74 | 58 | static int cpu_has_cpufreq(unsigned int cpu) |
|---|
| 75 | 59 | { |
|---|
| 76 | 60 | struct cpufreq_policy policy; |
|---|
| 77 | | - if (!acpi_thermal_cpufreq_is_init || cpufreq_get_policy(&policy, cpu)) |
|---|
| 61 | + if (!acpi_processor_cpufreq_init || cpufreq_get_policy(&policy, cpu)) |
|---|
| 78 | 62 | return 0; |
|---|
| 79 | 63 | return 1; |
|---|
| 80 | 64 | } |
|---|
| 81 | | - |
|---|
| 82 | | -static int acpi_thermal_cpufreq_notifier(struct notifier_block *nb, |
|---|
| 83 | | - unsigned long event, void *data) |
|---|
| 84 | | -{ |
|---|
| 85 | | - struct cpufreq_policy *policy = data; |
|---|
| 86 | | - unsigned long max_freq = 0; |
|---|
| 87 | | - |
|---|
| 88 | | - if (event != CPUFREQ_ADJUST) |
|---|
| 89 | | - goto out; |
|---|
| 90 | | - |
|---|
| 91 | | - max_freq = ( |
|---|
| 92 | | - policy->cpuinfo.max_freq * |
|---|
| 93 | | - (100 - reduction_pctg(policy->cpu) * 20) |
|---|
| 94 | | - ) / 100; |
|---|
| 95 | | - |
|---|
| 96 | | - cpufreq_verify_within_limits(policy, 0, max_freq); |
|---|
| 97 | | - |
|---|
| 98 | | - out: |
|---|
| 99 | | - return 0; |
|---|
| 100 | | -} |
|---|
| 101 | | - |
|---|
| 102 | | -static struct notifier_block acpi_thermal_cpufreq_notifier_block = { |
|---|
| 103 | | - .notifier_call = acpi_thermal_cpufreq_notifier, |
|---|
| 104 | | -}; |
|---|
| 105 | 65 | |
|---|
| 106 | 66 | static int cpufreq_get_max_state(unsigned int cpu) |
|---|
| 107 | 67 | { |
|---|
| .. | .. |
|---|
| 121 | 81 | |
|---|
| 122 | 82 | static int cpufreq_set_cur_state(unsigned int cpu, int state) |
|---|
| 123 | 83 | { |
|---|
| 124 | | - int i; |
|---|
| 84 | + struct cpufreq_policy *policy; |
|---|
| 85 | + struct acpi_processor *pr; |
|---|
| 86 | + unsigned long max_freq; |
|---|
| 87 | + int i, ret; |
|---|
| 125 | 88 | |
|---|
| 126 | 89 | if (!cpu_has_cpufreq(cpu)) |
|---|
| 127 | 90 | return 0; |
|---|
| .. | .. |
|---|
| 134 | 97 | * frequency. |
|---|
| 135 | 98 | */ |
|---|
| 136 | 99 | for_each_online_cpu(i) { |
|---|
| 137 | | - if (topology_physical_package_id(i) == |
|---|
| 100 | + if (topology_physical_package_id(i) != |
|---|
| 138 | 101 | topology_physical_package_id(cpu)) |
|---|
| 139 | | - cpufreq_update_policy(i); |
|---|
| 102 | + continue; |
|---|
| 103 | + |
|---|
| 104 | + pr = per_cpu(processors, i); |
|---|
| 105 | + |
|---|
| 106 | + if (unlikely(!freq_qos_request_active(&pr->thermal_req))) |
|---|
| 107 | + continue; |
|---|
| 108 | + |
|---|
| 109 | + policy = cpufreq_cpu_get(i); |
|---|
| 110 | + if (!policy) |
|---|
| 111 | + return -EINVAL; |
|---|
| 112 | + |
|---|
| 113 | + max_freq = (policy->cpuinfo.max_freq * (100 - reduction_pctg(i) * 20)) / 100; |
|---|
| 114 | + |
|---|
| 115 | + cpufreq_cpu_put(policy); |
|---|
| 116 | + |
|---|
| 117 | + ret = freq_qos_update_request(&pr->thermal_req, max_freq); |
|---|
| 118 | + if (ret < 0) { |
|---|
| 119 | + pr_warn("Failed to update thermal freq constraint: CPU%d (%d)\n", |
|---|
| 120 | + pr->id, ret); |
|---|
| 121 | + } |
|---|
| 140 | 122 | } |
|---|
| 141 | 123 | return 0; |
|---|
| 142 | 124 | } |
|---|
| 143 | 125 | |
|---|
| 144 | | -void acpi_thermal_cpufreq_init(void) |
|---|
| 126 | +void acpi_thermal_cpufreq_init(struct cpufreq_policy *policy) |
|---|
| 145 | 127 | { |
|---|
| 146 | | - int i; |
|---|
| 128 | + unsigned int cpu; |
|---|
| 147 | 129 | |
|---|
| 148 | | - i = cpufreq_register_notifier(&acpi_thermal_cpufreq_notifier_block, |
|---|
| 149 | | - CPUFREQ_POLICY_NOTIFIER); |
|---|
| 150 | | - if (!i) |
|---|
| 151 | | - acpi_thermal_cpufreq_is_init = 1; |
|---|
| 130 | + for_each_cpu(cpu, policy->related_cpus) { |
|---|
| 131 | + struct acpi_processor *pr = per_cpu(processors, cpu); |
|---|
| 132 | + int ret; |
|---|
| 133 | + |
|---|
| 134 | + if (!pr) |
|---|
| 135 | + continue; |
|---|
| 136 | + |
|---|
| 137 | + ret = freq_qos_add_request(&policy->constraints, |
|---|
| 138 | + &pr->thermal_req, |
|---|
| 139 | + FREQ_QOS_MAX, INT_MAX); |
|---|
| 140 | + if (ret < 0) |
|---|
| 141 | + pr_err("Failed to add freq constraint for CPU%d (%d)\n", |
|---|
| 142 | + cpu, ret); |
|---|
| 143 | + } |
|---|
| 152 | 144 | } |
|---|
| 153 | 145 | |
|---|
| 154 | | -void acpi_thermal_cpufreq_exit(void) |
|---|
| 146 | +void acpi_thermal_cpufreq_exit(struct cpufreq_policy *policy) |
|---|
| 155 | 147 | { |
|---|
| 156 | | - if (acpi_thermal_cpufreq_is_init) |
|---|
| 157 | | - cpufreq_unregister_notifier |
|---|
| 158 | | - (&acpi_thermal_cpufreq_notifier_block, |
|---|
| 159 | | - CPUFREQ_POLICY_NOTIFIER); |
|---|
| 148 | + unsigned int cpu; |
|---|
| 160 | 149 | |
|---|
| 161 | | - acpi_thermal_cpufreq_is_init = 0; |
|---|
| 150 | + for_each_cpu(cpu, policy->related_cpus) { |
|---|
| 151 | + struct acpi_processor *pr = per_cpu(processors, cpu); |
|---|
| 152 | + |
|---|
| 153 | + if (pr) |
|---|
| 154 | + freq_qos_remove_request(&pr->thermal_req); |
|---|
| 155 | + } |
|---|
| 162 | 156 | } |
|---|
| 163 | | - |
|---|
| 164 | 157 | #else /* ! CONFIG_CPU_FREQ */ |
|---|
| 165 | 158 | static int cpufreq_get_max_state(unsigned int cpu) |
|---|
| 166 | 159 | { |
|---|