What:        /sys/class/scsi_host/hostX/isci_id
Date:        June 2011
Contact:    Dave Jiang <dave.jiang@intel.com>
Description:
       This file contains the enumerated host ID for the Intel
       SCU controller. The Intel(R) C600 Series Chipset SATA/SAS
       Storage Control Unit embeds up to two 4-port controllers in
       a single PCI device.  The controllers are enumerated in order
       which usually means the lowest number scsi_host corresponds
       with the first controller, but this association is not
       guaranteed.  The 'isci_id' attribute unambiguously identifies
       the controller index: '0' for the first controller,
       '1' for the second.
 
What:        /sys/class/scsi_host/hostX/acciopath_status
Date:        November 2013
Contact:    Stephen M. Cameron <scameron@beardog.cce.hp.com>
Description:    This file contains the current status of the "SSD Smart Path"
       feature of HP Smart Array RAID controllers using the hpsa
       driver.  SSD Smart Path, when enabled permits the driver to
       send i/o requests directly to physical devices that are part
       of a logical drive, bypassing the controllers firmware RAID
       stack for a performance advantage when possible.  A value of
       '1' indicates the feature is enabled, and the controller may
       use the direct i/o path to physical devices.  A value of zero
       means the feature is disabled and the controller may not use
       the direct i/o path to physical devices.  This setting is
       controller wide, affecting all configured logical drives on the
       controller.  This file is readable and writable.