What:        /sys/bus/iio/devices/iio:deviceX/calibration_auto_enable
Date:        June 2020
KernelVersion:    5.8
Contact:    linux-iio@vger.kernel.org
Description:
       Contaminants build-up in the measurement chamber or optical
       elements deterioration leads to sensor drift.
 
       One can compensate for sensor drift by using automatic self
       calibration procedure (asc).
 
       Writing 1 or 0 to this attribute will respectively activate or
       deactivate asc.
 
       Upon reading current asc status is returned.
 
What:        /sys/bus/iio/devices/iio:deviceX/calibration_forced_value
Date:        June 2020
KernelVersion:    5.8
Contact:    linux-iio@vger.kernel.org
Description:
       Contaminants build-up in the measurement chamber or optical
       elements deterioration leads to sensor drift.
 
       One can compensate for sensor drift by using forced
       recalibration (frc). This is useful in case there's known
       co2 reference available nearby the sensor.
 
       Picking value from the range [400 1 2000] and writing it to the
       sensor will set frc.
 
       Upon reading current frc value is returned. Note that after
       power cycling default value (i.e 400) is returned even though
       internally sensor had recalibrated itself.