What:        /sys/bus/iio/devices/iio:deviceX/in_voltageY_sensing_mode
Date:        August 2015
KernelVersion:    4.2.0
Contact:    source@cogentembedded.com
Description:
       Program sensor type for threshold detector inputs.
       Could be either "GND-Open" or "Supply-Open" mode. Y is a
       threshold detector input channel. Channels 0..7, 8..15, 16..23
       and 24..31 has common sensor types.
 
What:        /sys/bus/iio/devices/iio:deviceX/events/in_voltageY_thresh_falling_value
Date:        August 2015
KernelVersion:    4.2.0
Contact:    source@cogentembedded.com
Description:
       Channel Y low voltage threshold. If sensor input voltage goes lower then
       this value then the threshold falling event is pushed.
       Depending on in_voltageY_sensing_mode the low voltage threshold
       is separately set for "GND-Open" and "Supply-Open" modes.
       Channels 0..31 have common low threshold values, but could have different
       sensing_modes.
 
       The low voltage threshold range is between 2..21V.
       Hysteresis between low and high thresholds can not be lower then 2 and
       can not be odd.
 
       If falling threshold results hysteresis to odd value then rising
       threshold is automatically subtracted by one.
 
What:        /sys/bus/iio/devices/iio:deviceX/events/in_voltageY_thresh_rising_value
Date:        August 2015
KernelVersion:    4.2.0
Contact:    source@cogentembedded.com
Description:
       Channel Y high voltage threshold. If sensor input voltage goes higher then
       this value then the threshold rising event is pushed.
       Depending on in_voltageY_sensing_mode the high voltage threshold
       is separately set for "GND-Open" and "Supply-Open" modes.
 
       Channels 0..31 have common high threshold values, but could have different
       sensing_modes.
 
       The high voltage threshold range is between 3..22V.
       Hysteresis between low and high thresholds can not be lower then 2 and
       can not be odd.
 
       If rising threshold results hysteresis to odd value then falling
       threshold is automatically appended by one.