What:        /sys/bus/iio/devices/triggerX/trigger_polarity
KernelVersion:    4.11
Contact:    fabrice.gasnier@st.com
Description:
       The STM32 ADC can be configured to use external trigger sources
       (e.g. timers, pwm or exti gpio). Then, it can be tuned to start
       conversions on external trigger by either:
       - "rising-edge"
       - "falling-edge"
       - "both-edges".
       Reading returns current trigger polarity.
       Writing value before enabling conversions sets trigger polarity.
 
What:        /sys/bus/iio/devices/triggerX/trigger_polarity_available
KernelVersion:    4.11
Contact:    fabrice.gasnier@st.com
Description:
       List all available trigger_polarity settings.