* Holt HI-311X stand-alone CAN controller device tree bindings
 
Required properties:
 - compatible: Should be one of the following:
   - "holt,hi3110" for HI-3110
 - reg: SPI chip select.
 - clocks: The clock feeding the CAN controller.
 - interrupts: Should contain IRQ line for the CAN controller.
 
Optional properties:
 - vdd-supply: Regulator that powers the CAN controller.
 - xceiver-supply: Regulator that powers the CAN transceiver.
 
Example:
   can0: can@1 {
       compatible = "holt,hi3110";
       reg = <1>;
       clocks = <&clk32m>;
       interrupt-parent = <&gpio4>;
       interrupts = <13 IRQ_TYPE_LEVEL_HIGH>;
       vdd-supply = <&reg5v0>;
       xceiver-supply = <&reg5v0>;
   };