ST Microelectronics Mailbox Driver
 
Each ST Mailbox IP currently consists of 4 instances of 32 channels.  Messages
are passed between Application and Remote processors using shared memory.
 
Controller
----------
 
Required properties:
- compatible        : Should be "st,stih407-mailbox"
- reg            : Offset and length of the device's register set
- mbox-name        : Name of the mailbox
- #mbox-cells:        : Must be 2
             <&phandle instance channel direction>
               phandle   : Label name of controller
               instance  : Instance number
               channel   : Channel number
 
Optional properties
- interrupts        : Contains the IRQ line for a Rx mailbox
 
Example:
 
mailbox0: mailbox@0  {
   compatible    = "st,stih407-mailbox";
   reg        = <0x08f00000 0x1000>;
   interrupts    = <GIC_SPI 1 IRQ_TYPE_NONE>;
   #mbox-cells    = <2>;
   mbox-name    = "a9";
};
 
Client
------
 
Required properties:
- compatible        : Many (See the client docs)
- reg            : Shared (between Application and Remote) memory address
- mboxes        : Standard property to specify a Mailbox (See ./mailbox.txt)
             Cells must match 'mbox-cells' (See Controller docs above)
 
Optional properties
- mbox-names        : Name given to channels seen in the 'mboxes' property.
 
Example:
 
mailbox_test {
   compatible    = "mailbox-test";
   reg        = <0x[shared_memory_address], [shared_memory_size]>;
   mboxes        = <&mailbox2 0 1>, <&mailbox0 2 1>;
   mbox-names    = "tx",    "rx";
};