SP810 System Controller
-----------------------
 
Required properties:
 
- compatible:    standard compatible string for a Primecell peripheral,
       see Documentation/devicetree/bindings/arm/primecell.txt
       for more details
       should be: "arm,sp810", "arm,primecell"
 
- reg:        standard registers property, physical address and size
       of the control registers
 
- clock-names:    from the common clock bindings, for more details see
       Documentation/devicetree/bindings/clock/clock-bindings.txt;
       should be: "refclk", "timclk", "apb_pclk"
 
- clocks:    from the common clock bindings, phandle and clock
       specifier pairs for the entries of clock-names property
 
- #clock-cells: from the common clock bindings;
       should be: <1>
 
- clock-output-names: from the common clock bindings;
       should be: "timerclken0", "timerclken1", "timerclken2", "timerclken3"
 
- assigned-clocks: from the common clock binding;
       should be: clock specifier for each output clock of this
       provider node
 
- assigned-clock-parents: from the common clock binding;
       should be: phandle of input clock listed in clocks
       property with the highest frequency
 
Example:
   v2m_sysctl: sysctl@20000 {
       compatible = "arm,sp810", "arm,primecell";
       reg = <0x020000 0x1000>;
       clocks = <&v2m_refclk32khz>, <&v2m_refclk1mhz>, <&smbclk>;
       clock-names = "refclk", "timclk", "apb_pclk";
       #clock-cells = <1>;
       clock-output-names = "timerclken0", "timerclken1", "timerclken2", "timerclken3";
       assigned-clocks = <&v2m_sysctl 0>, <&v2m_sysctl 1>, <&v2m_sysctl 3>, <&v2m_sysctl 3>;
       assigned-clock-parents = <&v2m_refclk1mhz>, <&v2m_refclk1mhz>, <&v2m_refclk1mhz>, <&v2m_refclk1mhz>;
 
   };