* UniPhier Thermal bindings
 
This describes the devicetree bindings for thermal monitor supported by
PVT(Process, Voltage and Temperature) monitoring unit implemented on Socionext
UniPhier SoCs.
 
Required properties:
- compatible :
  - "socionext,uniphier-pxs2-thermal" : For UniPhier PXs2 SoC
  - "socionext,uniphier-ld20-thermal" : For UniPhier LD20 SoC
  - "socionext,uniphier-pxs3-thermal" : For UniPhier PXs3 SoC
- interrupts : IRQ for the temperature alarm
- #thermal-sensor-cells : Should be 0. See ./thermal.txt for details.
 
Optional properties:
- socionext,tmod-calibration: A pair of calibrated values referred from PVT,
                              in case that the values aren't set on SoC,
                              like a reference board.
 
Example:
 
   sysctrl@61840000 {
       compatible = "socionext,uniphier-ld20-sysctrl",
                "simple-mfd", "syscon";
       reg = <0x61840000 0x10000>;
       ...
       pvtctl: pvtctl {
           compatible = "socionext,uniphier-ld20-thermal";
           interrupts = <0 3 1>;
           #thermal-sensor-cells = <0>;
       };
       ...
   };
 
   thermal-zones {
       cpu_thermal {
           polling-delay-passive = <250>;    /* 250ms */
           polling-delay = <1000>;        /* 1000ms */
           thermal-sensors = <&pvtctl>;
 
           trips {
               cpu_crit: cpu_crit {
                   temperature = <110000>;    /* 110C */
                   hysteresis = <2000>;
                   type = "critical";
               };
               cpu_alert: cpu_alert {
                   temperature = <100000>;    /* 100C */
                   hysteresis = <2000>;
                   type = "passive";
               };
           };
 
           cooling-maps {
               map0 {
                   trip = <&cpu_alert>;
                   cooling-device = <&cpu0 (-1) (-1)>;
               };
               map1 {
                   trip = <&cpu_alert>;
                   cooling-device = <&cpu2 (-1) (-1)>;
               };
           };
       };
   };