Current Sense Shunt
===================
 
When an io-channel measures the voltage over a current sense shunt,
the interesting measurement is almost always the current through the
shunt, not the voltage over it. This binding describes such a current
sense circuit.
 
Required properties:
- compatible : "current-sense-shunt"
- io-channels : Channel node of a voltage io-channel.
- shunt-resistor-micro-ohms : The shunt resistance in microohms.
 
Example:
The system current is measured by measuring the voltage over a
3.3 ohms shunt resistor.
 
sysi {
   compatible = "current-sense-shunt";
   io-channels = <&tiadc 0>;
 
   /* Divide the voltage by 3300000/1000000 (or 3.3) for the current. */
   shunt-resistor-micro-ohms = <3300000>;
};
 
&i2c {
   tiadc: adc@48 {
       compatible = "ti,ads1015";
       reg = <0x48>;
       #io-channel-cells = <1>;
 
       #address-cells = <1>;
       #size-cells = <0>;
 
       channel@0 { /* IN0,IN1 differential */
           reg = <0>;
           ti,gain = <1>;
           ti,datarate = <4>;
       };
   };
};