hc
2024-12-19 9370bb92b2d16684ee45cf24e879c93c509162da
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
// SPDX-License-Identifier: GPL-2.0-only
/*
 * INT3402 thermal driver for memory temperature reporting
 *
 * Copyright (C) 2014, Intel Corporation
 * Authors: Aaron Lu <aaron.lu@intel.com>
 */
 
#include <linux/module.h>
#include <linux/platform_device.h>
#include <linux/acpi.h>
#include <linux/thermal.h>
#include "int340x_thermal_zone.h"
 
#define INT3402_PERF_CHANGED_EVENT    0x80
#define INT3402_THERMAL_EVENT        0x90
 
struct int3402_thermal_data {
   acpi_handle *handle;
   struct int34x_thermal_zone *int340x_zone;
};
 
static void int3402_notify(acpi_handle handle, u32 event, void *data)
{
   struct int3402_thermal_data *priv = data;
 
   if (!priv)
       return;
 
   switch (event) {
   case INT3402_PERF_CHANGED_EVENT:
       break;
   case INT3402_THERMAL_EVENT:
       int340x_thermal_zone_device_update(priv->int340x_zone,
                          THERMAL_TRIP_VIOLATED);
       break;
   default:
       break;
   }
}
 
static int int3402_thermal_probe(struct platform_device *pdev)
{
   struct acpi_device *adev = ACPI_COMPANION(&pdev->dev);
   struct int3402_thermal_data *d;
   int ret;
 
   if (!acpi_has_method(adev->handle, "_TMP"))
       return -ENODEV;
 
   d = devm_kzalloc(&pdev->dev, sizeof(*d), GFP_KERNEL);
   if (!d)
       return -ENOMEM;
 
   d->int340x_zone = int340x_thermal_zone_add(adev, NULL);
   if (IS_ERR(d->int340x_zone))
       return PTR_ERR(d->int340x_zone);
 
   ret = acpi_install_notify_handler(adev->handle,
                     ACPI_DEVICE_NOTIFY,
                     int3402_notify,
                     d);
   if (ret) {
       int340x_thermal_zone_remove(d->int340x_zone);
       return ret;
   }
 
   d->handle = adev->handle;
   platform_set_drvdata(pdev, d);
 
   return 0;
}
 
static int int3402_thermal_remove(struct platform_device *pdev)
{
   struct int3402_thermal_data *d = platform_get_drvdata(pdev);
 
   acpi_remove_notify_handler(d->handle,
                  ACPI_DEVICE_NOTIFY, int3402_notify);
   int340x_thermal_zone_remove(d->int340x_zone);
 
   return 0;
}
 
static const struct acpi_device_id int3402_thermal_match[] = {
   {"INT3402", 0},
   {}
};
 
MODULE_DEVICE_TABLE(acpi, int3402_thermal_match);
 
static struct platform_driver int3402_thermal_driver = {
   .probe = int3402_thermal_probe,
   .remove = int3402_thermal_remove,
   .driver = {
          .name = "int3402 thermal",
          .acpi_match_table = int3402_thermal_match,
          },
};
 
module_platform_driver(int3402_thermal_driver);
 
MODULE_DESCRIPTION("INT3402 Thermal driver");
MODULE_LICENSE("GPL");