hc
2024-12-19 9370bb92b2d16684ee45cf24e879c93c509162da
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
# SPDX-License-Identifier: GPL-2.0-only
config NVME_CORE
   tristate
   select BLK_DEV_INTEGRITY_T10 if BLK_DEV_INTEGRITY
 
config BLK_DEV_NVME
   tristate "NVM Express block device"
   depends on PCI && BLOCK
   select NVME_CORE
   help
     The NVM Express driver is for solid state drives directly
     connected to the PCI or PCI Express bus.  If you know you
     don't have one of these, it is safe to answer N.
 
     To compile this driver as a module, choose M here: the
     module will be called nvme.
 
config NVME_MULTIPATH
   bool "NVMe multipath support"
   depends on NVME_CORE
   help
      This option enables support for multipath access to NVMe
      subsystems.  If this option is enabled only a single
      /dev/nvmeXnY device will show up for each NVMe namespaces,
      even if it is accessible through multiple controllers.
 
config NVME_HWMON
   bool "NVMe hardware monitoring"
   depends on (NVME_CORE=y && HWMON=y) || (NVME_CORE=m && HWMON)
   help
     This provides support for NVMe hardware monitoring. If enabled,
     a hardware monitoring device will be created for each NVMe drive
     in the system.
 
config NVME_FABRICS
   tristate
 
config NVME_RDMA
   tristate "NVM Express over Fabrics RDMA host driver"
   depends on INFINIBAND && INFINIBAND_ADDR_TRANS && BLOCK
   select NVME_CORE
   select NVME_FABRICS
   select SG_POOL
   help
     This provides support for the NVMe over Fabrics protocol using
     the RDMA (Infiniband, RoCE, iWarp) transport.  This allows you
     to use remote block devices exported using the NVMe protocol set.
 
     To configure a NVMe over Fabrics controller use the nvme-cli tool
     from https://github.com/linux-nvme/nvme-cli.
 
     If unsure, say N.
 
config NVME_FC
   tristate "NVM Express over Fabrics FC host driver"
   depends on BLOCK
   depends on HAS_DMA
   select NVME_CORE
   select NVME_FABRICS
   select SG_POOL
   help
     This provides support for the NVMe over Fabrics protocol using
     the FC transport.  This allows you to use remote block devices
     exported using the NVMe protocol set.
 
     To configure a NVMe over Fabrics controller use the nvme-cli tool
     from https://github.com/linux-nvme/nvme-cli.
 
     If unsure, say N.
 
config NVME_TCP
   tristate "NVM Express over Fabrics TCP host driver"
   depends on INET
   depends on BLOCK
   select NVME_CORE
   select NVME_FABRICS
   select CRYPTO
   select CRYPTO_CRC32C
   help
     This provides support for the NVMe over Fabrics protocol using
     the TCP transport.  This allows you to use remote block devices
     exported using the NVMe protocol set.
 
     To configure a NVMe over Fabrics controller use the nvme-cli tool
     from https://github.com/linux-nvme/nvme-cli.
 
     If unsure, say N.