UniPhier UART controller
 
Required properties:
- compatible: should be "socionext,uniphier-uart".
- reg: offset and length of the register set for the device.
- interrupts: a single interrupt specifier.
- clocks: phandle to the input clock.
 
Optional properties:
- fifo-size: the RX/TX FIFO size.  Defaults to 64 if not specified.
 
Example:
   aliases {
       serial0 = &serial0;
   };
 
   serial0: serial@54006800 {
       compatible = "socionext,uniphier-uart";
       reg = <0x54006800 0x40>;
       interrupts = <0 33 4>;
       clocks = <&uart_clk>;
       fifo-size = <64>;
   };