Ralink Watchdog Timers
 
Required properties:
- compatible: must be "ralink,rt2880-wdt"
- reg: physical base address of the controller and length of the register range
 
Optional properties:
- interrupts: Specify the INTC interrupt number
 
Example:
 
   watchdog@120 {
       compatible = "ralink,rt2880-wdt";
       reg = <0x120 0x10>;
 
       interrupt-parent = <&intc>;
       interrupts = <1>;
   };