hc
2024-10-22 8ac6c7a54ed1b98d142dce24b11c6de6a1e239a5
1
2
3
4
5
6
7
8
9
10
11
12
What:        /sys/bus/w1/devices/.../w1_master_timeout_us
Date:        April 2015
Contact:    Dmitry Khromov <dk@icelogic.net>
Description:    Bus scanning interval, microseconds component.
       Some of 1-Wire devices commonly associated with physical access
       control systems are attached/generate presence for as short as
       100 ms - hence the tens-to-hundreds milliseconds scan intervals
       are required.
 
       see Documentation/w1/w1-generic.rst for detailed information.
Users:        any user space application which wants to know bus scanning
       interval