Bindings for a fan connected to the PWM lines
 
Required properties:
- compatible    : "pwm-fan"
- pwms        : the PWM that is used to control the PWM fan
- cooling-levels      : PWM duty cycle values in a range from 0 to 255
           which correspond to thermal cooling states
 
Example:
   fan0: pwm-fan {
       compatible = "pwm-fan";
       cooling-min-state = <0>;
       cooling-max-state = <3>;
       #cooling-cells = <2>;
       pwms = <&pwm 0 10000 0>;
       cooling-levels = <0 102 170 230>;
   };
 
   thermal-zones {
       cpu_thermal: cpu-thermal {
                thermal-sensors = <&tmu 0>;
                polling-delay-passive = <0>;
                polling-delay = <0>;
                trips {
                   cpu_alert1: cpu-alert1 {
                           temperature = <100000>; /* millicelsius */
                           hysteresis = <2000>; /* millicelsius */
                           type = "passive";
                   };
                };
                cooling-maps {
                   map0 {
                           trip = <&cpu_alert1>;
                           cooling-device = <&fan0 0 1>;
                   };
                };
       };