ST-Ericsson U300 apptimer
 
Required properties:
 
- compatible : should be "stericsson,u300-apptimer"
- reg : Specifies base physical address and size of the registers.
- interrupts : A list of 4 interrupts; one for each subtimer. These
  are, in order: OS (operating system), DD (device driver) both
  adopted for EPOC/Symbian with two specific IRQs for these tasks,
  then GP1 and GP2, which are general-purpose timers.
 
Example:
 
timer {
   compatible = "stericsson,u300-apptimer";
   reg = <0xc0014000 0x1000>;
   interrupts = <24 25 26 27>;
};