Lantiq XWAY SoC RCU binding 
 | 
=========================== 
 | 
  
 | 
This binding describes the RCU (reset controller unit) multifunction device, 
 | 
where each sub-device has it's own set of registers. 
 | 
  
 | 
The RCU register range is used for multiple purposes. Mostly one device 
 | 
uses one or multiple register exclusively, but for some registers some 
 | 
bits are for one driver and some other bits are for a different driver. 
 | 
With this patch all accesses to the RCU registers will go through 
 | 
syscon. 
 | 
  
 | 
  
 | 
------------------------------------------------------------------------------- 
 | 
Required properties: 
 | 
- compatible    : The first and second values must be: 
 | 
          "lantiq,xrx200-rcu", "simple-mfd", "syscon" 
 | 
- reg        : The address and length of the system control registers 
 | 
  
 | 
  
 | 
------------------------------------------------------------------------------- 
 | 
Example of the RCU bindings on a xRX200 SoC: 
 | 
    rcu0: rcu@203000 { 
 | 
        compatible = "lantiq,xrx200-rcu", "simple-mfd", "syscon"; 
 | 
        reg = <0x203000 0x100>; 
 | 
        ranges = <0x0 0x203000 0x100>; 
 | 
        big-endian; 
 | 
  
 | 
        gphy0: gphy@20 { 
 | 
            compatible = "lantiq,xrx200a2x-gphy"; 
 | 
            reg = <0x20 0x4>; 
 | 
  
 | 
            resets = <&reset0 31 30>, <&reset1 7 7>; 
 | 
            reset-names = "gphy", "gphy2"; 
 | 
            lantiq,gphy-mode = <GPHY_MODE_GE>; 
 | 
        }; 
 | 
  
 | 
        gphy1: gphy@68 { 
 | 
            compatible = "lantiq,xrx200a2x-gphy"; 
 | 
            reg = <0x68 0x4>; 
 | 
  
 | 
            resets = <&reset0 29 28>, <&reset1 6 6>; 
 | 
            reset-names = "gphy", "gphy2"; 
 | 
            lantiq,gphy-mode = <GPHY_MODE_GE>; 
 | 
        }; 
 | 
  
 | 
        reset0: reset-controller@10 { 
 | 
            compatible = "lantiq,xrx200-reset"; 
 | 
            reg = <0x10 4>, <0x14 4>; 
 | 
  
 | 
            #reset-cells = <2>; 
 | 
        }; 
 | 
  
 | 
        reset1: reset-controller@48 { 
 | 
            compatible = "lantiq,xrx200-reset"; 
 | 
            reg = <0x48 4>, <0x24 4>; 
 | 
  
 | 
            #reset-cells = <2>; 
 | 
        }; 
 | 
  
 | 
        usb_phy0: usb2-phy@18 { 
 | 
            compatible = "lantiq,xrx200-usb2-phy"; 
 | 
            reg = <0x18 4>, <0x38 4>; 
 | 
  
 | 
            resets = <&reset1 4 4>, <&reset0 4 4>; 
 | 
            reset-names = "phy", "ctrl"; 
 | 
            #phy-cells = <0>; 
 | 
        }; 
 | 
  
 | 
        usb_phy1: usb2-phy@34 { 
 | 
            compatible = "lantiq,xrx200-usb2-phy"; 
 | 
            reg = <0x34 4>, <0x3C 4>; 
 | 
  
 | 
            resets = <&reset1 5 4>, <&reset0 4 4>; 
 | 
            reset-names = "phy", "ctrl"; 
 | 
            #phy-cells = <0>; 
 | 
        }; 
 | 
  
 | 
        reboot@10 { 
 | 
            compatible = "syscon-reboot"; 
 | 
            reg = <0x10 4>; 
 | 
  
 | 
            regmap = <&rcu0>; 
 | 
            offset = <0x10>; 
 | 
            mask = <0x40000000>; 
 | 
        }; 
 | 
    }; 
 |