Binding for Texas Instruments ADPLL clock. 
 | 
  
 | 
Binding status: Unstable - ABI compatibility may be broken in the future 
 | 
  
 | 
This binding uses the common clock binding[1]. It assumes a 
 | 
register-mapped ADPLL with two to three selectable input clocks 
 | 
and three to four children. 
 | 
  
 | 
[1] Documentation/devicetree/bindings/clock/clock-bindings.txt 
 | 
  
 | 
Required properties: 
 | 
- compatible : shall be one of "ti,dm814-adpll-s-clock" or 
 | 
  "ti,dm814-adpll-lj-clock" depending on the type of the ADPLL 
 | 
- #clock-cells : from common clock binding; shall be set to 1. 
 | 
- clocks : link phandles of parent clocks clkinp and clkinpulow, note 
 | 
  that the adpll-s-clock also has an optional clkinphif 
 | 
- reg : address and length of the register set for controlling the ADPLL. 
 | 
  
 | 
Examples: 
 | 
    adpll_mpu_ck: adpll@40 { 
 | 
        #clock-cells = <1>; 
 | 
        compatible = "ti,dm814-adpll-s-clock"; 
 | 
        reg = <0x40 0x40>; 
 | 
        clocks = <&devosc_ck &devosc_ck &devosc_ck>; 
 | 
        clock-names = "clkinp", "clkinpulow", "clkinphif"; 
 | 
        clock-output-names = "481c5040.adpll.dcoclkldo", 
 | 
                     "481c5040.adpll.clkout", 
 | 
                     "481c5040.adpll.clkoutx2", 
 | 
                     "481c5040.adpll.clkouthif"; 
 | 
    }; 
 | 
  
 | 
    adpll_dsp_ck: adpll@80 { 
 | 
        #clock-cells = <1>; 
 | 
        compatible = "ti,dm814-adpll-lj-clock"; 
 | 
        reg = <0x80 0x30>; 
 | 
        clocks = <&devosc_ck &devosc_ck>; 
 | 
        clock-names = "clkinp", "clkinpulow"; 
 | 
        clock-output-names = "481c5080.adpll.dcoclkldo", 
 | 
                     "481c5080.adpll.clkout", 
 | 
                     "481c5080.adpll.clkoutldo"; 
 | 
    }; 
 |