NVIDIA Tegra Power Management Controller (PMC) 
 | 
  
 | 
Required properties: 
 | 
- compatible: Should contain one of the following: 
 | 
  - "nvidia,tegra186-pmc": for Tegra186 
 | 
  - "nvidia,tegra194-pmc": for Tegra194 
 | 
- reg: Must contain an (offset, length) pair of the register set for each 
 | 
  entry in reg-names. 
 | 
- reg-names: Must include the following entries: 
 | 
  - "pmc" 
 | 
  - "wake" 
 | 
  - "aotag" 
 | 
  - "scratch" 
 | 
  - "misc" (Only for Tegra194) 
 | 
  
 | 
Optional properties: 
 | 
- nvidia,invert-interrupt: If present, inverts the PMU interrupt signal. 
 | 
  
 | 
Example: 
 | 
  
 | 
SoC DTSI: 
 | 
  
 | 
    pmc@c3600000 { 
 | 
        compatible = "nvidia,tegra186-pmc"; 
 | 
        reg = <0 0x0c360000 0 0x10000>, 
 | 
              <0 0x0c370000 0 0x10000>, 
 | 
              <0 0x0c380000 0 0x10000>, 
 | 
              <0 0x0c390000 0 0x10000>; 
 | 
        reg-names = "pmc", "wake", "aotag", "scratch"; 
 | 
    }; 
 | 
  
 | 
Board DTS: 
 | 
  
 | 
    pmc@c360000 { 
 | 
        nvidia,invert-interrupt; 
 | 
    }; 
 |