hc
2023-11-20 3c9370f7b6bffd697c9907a7139e9df5b0d4b9df
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
NVIDIA Tegra114 SPI controller.
 
Required properties:
- compatible : For Tegra114, must contain "nvidia,tegra114-spi".
  Otherwise, must contain '"nvidia,<chip>-spi", "nvidia,tegra114-spi"' where
  <chip> is tegra124, tegra132, or tegra210.
- reg: Should contain SPI registers location and length.
- interrupts: Should contain SPI interrupts.
- clock-names : Must include the following entries:
  - spi
- resets : Must contain an entry for each entry in reset-names.
  See ../reset/reset.txt for details.
- reset-names : Must include the following entries:
  - spi
- dmas : Must contain an entry for each entry in clock-names.
  See ../dma/dma.txt for details.
- dma-names : Must include the following entries:
  - rx
  - tx
- clocks : Must contain an entry for each entry in clock-names.
  See ../clocks/clock-bindings.txt for details.
 
Recommended properties:
- spi-max-frequency: Definition as per
                     Documentation/devicetree/bindings/spi/spi-bus.txt
Example:
 
spi@7000d600 {
   compatible = "nvidia,tegra114-spi";
   reg = <0x7000d600 0x200>;
   interrupts = <0 82 0x04>;
   spi-max-frequency = <25000000>;
   #address-cells = <1>;
   #size-cells = <0>;
   clocks = <&tegra_car 44>;
   clock-names = "spi";
   resets = <&tegra_car 44>;
   reset-names = "spi";
   dmas = <&apbdma 16>, <&apbdma 16>;
   dma-names = "rx", "tx";
};