Broadcom BCM63138 DSL System-on-a-Chip device tree bindings 
 | 
----------------------------------------------------------- 
 | 
  
 | 
Boards compatible with the BCM63138 DSL System-on-a-Chip should have the 
 | 
following properties: 
 | 
  
 | 
Required root node property: 
 | 
  
 | 
compatible: should be "brcm,bcm63138" 
 | 
  
 | 
An optional Boot lookup table Device Tree node is required for secondary CPU 
 | 
initialization as well as a 'resets' phandle to the correct PMB controller as 
 | 
defined in reset/brcm,bcm63138-pmb.txt for this secondary CPU, and an 
 | 
'enable-method' property. 
 | 
  
 | 
Required properties for the Boot lookup table node: 
 | 
- compatible: should be "brcm,bcm63138-bootlut" 
 | 
- reg: register base address and length for the Boot Lookup table 
 | 
  
 | 
Optional properties for the primary CPU node: 
 | 
- enable-method: should be "brcm,bcm63138" 
 | 
  
 | 
Optional properties for the secondary CPU node: 
 | 
- enable-method: should be "brcm,bcm63138" 
 | 
- resets: phandle to the relevant PMB controller, one integer indicating the internal 
 | 
  bus number, and a second integer indicating the address of the CPU in the PMB 
 | 
  internal bus number. 
 | 
  
 | 
Example: 
 | 
  
 | 
    cpus { 
 | 
        cpu@0 { 
 | 
            compatible = "arm,cotex-a9"; 
 | 
            reg = <0>; 
 | 
            ... 
 | 
            enable-method = "brcm,bcm63138"; 
 | 
        }; 
 | 
  
 | 
        cpu@1 { 
 | 
            compatible = "arm,cortex-a9"; 
 | 
            reg = <1>; 
 | 
            ... 
 | 
            enable-method = "brcm,bcm63138"; 
 | 
            resets = <&pmb0 4 1>; 
 | 
        }; 
 | 
    }; 
 | 
  
 | 
    bootlut: bootlut@8000 { 
 | 
        compatible = "brcm,bcm63138-bootlut"; 
 | 
        reg = <0x8000 0x50>; 
 | 
    }; 
 | 
  
 | 
======= 
 | 
reboot 
 | 
------ 
 | 
Two nodes are required for software reboot: a timer node and a syscon-reboot node. 
 | 
  
 | 
Timer node: 
 | 
  
 | 
- compatible: Must be "brcm,bcm6328-timer", "syscon" 
 | 
- reg: Register base address and length 
 | 
  
 | 
Syscon reboot node: 
 | 
  
 | 
See Documentation/devicetree/bindings/power/reset/syscon-reboot.txt for the 
 | 
detailed list of properties, the two values defined below are specific to the 
 | 
BCM6328-style timer: 
 | 
  
 | 
- offset: Should be 0x34 to denote the offset of the TIMER_WD_TIMER_RESET register 
 | 
  from the beginning of the TIMER block 
 | 
- mask: Should be 1 for the SoftRst bit. 
 | 
  
 | 
Example: 
 | 
  
 | 
    timer: timer@80 { 
 | 
        compatible = "brcm,bcm6328-timer", "syscon"; 
 | 
        reg = <0x80 0x3c>; 
 | 
    }; 
 | 
  
 | 
    reboot { 
 | 
        compatible = "syscon-reboot"; 
 | 
        regmap = <&timer>; 
 | 
        offset = <0x34>; 
 | 
        mask = <0x1>; 
 | 
    }; 
 |