What:        /sys/bus/counter/devices/counterX/signalY/cable_fault
KernelVersion:    5.7
Contact:    linux-iio@vger.kernel.org
Description:
       Read-only attribute that indicates whether a differential
       encoder cable fault (not connected or loose wires) is detected
       for the respective channel of Signal Y. Valid attribute values
       are boolean. Detection must first be enabled via the
       corresponding cable_fault_enable attribute.
 
What:        /sys/bus/counter/devices/counterX/signalY/cable_fault_enable
KernelVersion:    5.7
Contact:    linux-iio@vger.kernel.org
Description:
       Whether detection of differential encoder cable faults for the
       respective channel of Signal Y is enabled. Valid attribute
       values are boolean.
 
What:        /sys/bus/counter/devices/counterX/signalY/filter_clock_prescaler
KernelVersion:    5.7
Contact:    linux-iio@vger.kernel.org
Description:
       Filter clock factor for input Signal Y. This prescaler value
       affects the inputs of both quadrature pair signals.
 
What:        /sys/bus/counter/devices/counterX/signalY/index_polarity
KernelVersion:    5.2
Contact:    linux-iio@vger.kernel.org
Description:
       Active level of index input Signal Y; irrelevant in
       non-synchronous load mode.
 
What:        /sys/bus/counter/devices/counterX/signalY/index_polarity_available
What:        /sys/bus/counter/devices/counterX/signalY/synchronous_mode_available
KernelVersion:    5.2
Contact:    linux-iio@vger.kernel.org
Description:
       Discrete set of available values for the respective Signal Y
       configuration are listed in this file.
 
What:        /sys/bus/counter/devices/counterX/signalY/synchronous_mode
KernelVersion:    5.2
Contact:    linux-iio@vger.kernel.org
Description:
       Configure the counter associated with Signal Y for
       non-synchronous or synchronous load mode. Synchronous load mode
       cannot be selected in non-quadrature (Pulse-Direction) clock
       mode.
 
       non-synchronous:
           A logic low level is the active level at this index
           input. The index function (as enabled via preset_enable)
           is performed directly on the active level of the index
           input.
 
       synchronous:
           Intended for interfacing with encoder Index output in
           quadrature clock mode. The active level is configured
           via index_polarity. The index function (as enabled via
           preset_enable) is performed synchronously with the
           quadrature clock on the active level of the index input.