# SPDX-License-Identifier: GPL-2.0-only
config INTEL_POWERCLAMP
   tristate "Intel PowerClamp idle injection driver"
   depends on X86
   depends on CPU_SUP_INTEL
   help
     Enable this to enable Intel PowerClamp idle injection driver. This
     enforce idle time which results in more package C-state residency. The
     user interface is exposed via generic thermal framework.
 
config X86_PKG_TEMP_THERMAL
   tristate "X86 package temperature thermal driver"
   depends on X86_THERMAL_VECTOR
   select THERMAL_GOV_USER_SPACE
   select THERMAL_WRITABLE_TRIPS
   default m
   help
     Enable this to register CPU digital sensor for package temperature as
     thermal zone. Each package will have its own thermal zone. There are
     two trip points which can be set by user to get notifications via thermal
     notification methods.
 
config INTEL_SOC_DTS_IOSF_CORE
   tristate
   depends on X86 && PCI
   select IOSF_MBI
   help
     This is becoming a common feature for Intel SoCs to expose the additional
     digital temperature sensors (DTSs) using side band interface (IOSF). This
     implements the common set of helper functions to register, get temperature
     and get/set thresholds on DTSs.
 
config INTEL_SOC_DTS_THERMAL
   tristate "Intel SoCs DTS thermal driver"
   depends on X86 && PCI && ACPI
   select INTEL_SOC_DTS_IOSF_CORE
   select THERMAL_WRITABLE_TRIPS
   help
     Enable this to register Intel SoCs (e.g. Bay Trail) platform digital
     temperature sensor (DTS). These SoCs have two additional DTSs in
     addition to DTSs on CPU cores. Each DTS will be registered as a
     thermal zone. There are two trip points. One of the trip point can
     be set by user mode programs to get notifications via Linux thermal
     notification methods.The other trip is a critical trip point, which
     was set by the driver based on the TJ MAX temperature.
 
config INTEL_QUARK_DTS_THERMAL
   tristate "Intel Quark DTS thermal driver"
   depends on X86_INTEL_QUARK
   help
     Enable this to register Intel Quark SoC (e.g. X1000) platform digital
     temperature sensor (DTS). For X1000 SoC, it has one on-die DTS.
     The DTS will be registered as a thermal zone. There are two trip points:
     hot & critical. The critical trip point default value is set by
     underlying BIOS/Firmware.
 
menu "ACPI INT340X thermal drivers"
source "drivers/thermal/intel/int340x_thermal/Kconfig"
endmenu
 
config INTEL_BXT_PMIC_THERMAL
   tristate "Intel Broxton PMIC thermal driver"
   depends on X86 && INTEL_SOC_PMIC_BXTWC
   select REGMAP
   help
     Select this driver for Intel Broxton PMIC with ADC channels monitoring
     system temperature measurements and alerts.
     This driver is used for monitoring the ADC channels of PMIC and handles
     the alert trip point interrupts and notifies the thermal framework with
     the trip point and temperature details of the zone.
 
config INTEL_PCH_THERMAL
   tristate "Intel PCH Thermal Reporting Driver"
   depends on X86 && PCI
   help
     Enable this to support thermal reporting on certain intel PCHs.
     Thermal reporting device will provide temperature reading,
     programmable trip points and other information.